UL3173 XLPE Insulated Wire-Rated temperature: 125ºC-Rated voltage: 600V-Reference Standard: UL758, UL1581, C22.2 No.210-Passes UL H & FT2 vertical flame test.-Uniform insulation thickness of wire to ensure easy stripping and cutting.-For internal wiring of electronic and electrical equi......
| Conductor | Insulation | Max. Cond Resistance at 20°C (Ω/km) | |||
| AWG | Construction (No./mm) | Diameter (mm) | Thickness (mm) | Diameter (mm) | |
| 26 | 7/0.16 | 0.48 | 0.81 | 2.10 | 150.0 |
| 24 | 7/0.20 | 0.60 | 0.80 | 2.20 | 94.2 |
| 22 | 17/0.16 | 0.76 | 0.80 | 2.36 | 59.4 |
| 20 | 26/0.16 | 0.94 | 0.81 | 2.55 | 36.7 |
| 18 | 41/0.16 | 1.18 | 0.82 | 2.80 | 23.2 |
| 16 | 26/0.254 | 1.49 | 0.81 | 3.10 | 14.6 |








Aerial Bundled Cable, ABC Cable, Overhead Cable, ASTM, BS, NFC, IEC, DIN Standard
2kv 5kv Flat or Round Submersible Oil Pump Cable
Thhn/Thwn Wire with Best Quality
0.6/1kv Aluminum Conductor PE Insulated Quadruplex ABC Cable
UL 1723 Standard RoHS Compliance 200c 300V Fluoroplastic FEP Wire Cables